Glass Wool · Preformed Pipe Section

Glass Wool Pipe Insulation

Insulvora manufactures preformed glass wool pipe insulation for straight pipeline and mechanical-service applications. Sections are supplied to specified pipe diameters and insulation thicknesses, with further product details confirmed against the project's operating conditions.

22–720 mmAvailable inner diameter
25–100 mmAvailable wall thickness
450°CMaximum working temperature

Glass Wool Pipe Insulation Specifications

Each preformed section fits around a straight pipe run. The inner diameter refers to the bore of the insulation section and is matched to the outside diameter of the pipe. Wall thickness is the depth of insulation surrounding the pipe.

Available Specification Range Glass Wool Pipe Section
Density40–80 kg/m³
Inner Diameter22–720 mm
Wall Thickness25–100 mm
Section Length1 m
Thermal Conductivity0.035–0.042 W/m·K
Maximum Working Temperature450°C

Typical Applications

Preformed pipe sections are suitable for straight runs in heating, hot-water, process and mechanical systems. Their cylindrical form can be simpler to install than wrapping a flat blanket around the pipe on site and helps provide consistent coverage along the run.

Elbows, tees, valves and flanges require matching fabricated insulation pieces or another approved treatment. Straight sections alone do not address these fittings.

Chilled-water and other below-ambient services need a continuous vapor-control layer with all joints sealed. Outdoor and damage-prone installations also need a suitable protective jacket. Position joints away from standing water, repeated mechanical stress and areas of concentrated maintenance activity where practicable.

Thermal Performance & Product Data

The thermal performance of a pipe section depends on its declared conductivity, insulation thickness, pipe diameter and operating temperature. On hot pipework, insulation reduces heat loss and surface temperature. On cold pipework, the design must also control heat gain and the risk of condensation.

The 450°C maximum working temperature is a limit for the insulation material; it does not establish the temperature rating of every facing, adhesive or protective jacket. Confirm the compatibility of the selected components with the operating conditions. Acoustic, fire and moisture performance should likewise be checked for the chosen pipe section and the complete installed construction. Heat-transfer calculations should account for conditions at the outer surface, including ambient air velocity.

Order Specifications & Quotation Requirements

Insulvora prepares quotations against the required pipe-section specifications and operating conditions. Pipe sections can be supplied in PE film or carton packing. For a project or bulk-supply enquiry, please identify:

Pipe dimensions

The actual pipe outside diameter or the required insulation inner diameter, together with insulation wall thickness.

Base specification

Required density, section length and quantity.

Service conditions

Operating temperature and relevant installation environment.

Additional configuration

Any facing, vapor-control, fire-classification or external protection requirements.

Request a Glass Wool Pipe Insulation Quote

Contact Insulvora to discuss suitable pipe sections and request a quotation for your project or bulk-supply order.