Elastomeric Insulation for HVAC, Refrigeration and Pipe Systems
Insulvora manufactures closed-cell elastomeric insulation in board, sheet and preformed pipe formats for HVAC, refrigeration, chilled-water piping and related mechanical systems. Flat products cover ducts, equipment and non-cylindrical surfaces, while pipe sleeves are selected to match the actual pipe size. Explore the product range below and use each specification page to check dimensions, thickness, density, facing and service conditions.
Elastomeric Insulation Boards, Sheets and Pipe Sleeves
The elastomeric insulation range includes five board and sheet products and seven pipe or sleeve products. Each card shows the density recorded for that product and links to its own specification page for further details.
B1 Rubber Foam Insulation Board
This NBR foam sheet uses closed-cell NBR/PVC rubber foam in B1-designated configurations, with listed 10–50 mm thicknesses, self-adhesive backing, and faced or unfaced options.
View B1 Rubber Foam Insulation Board
High Density Rubber Foam Board
High-density elastomeric foam insulation in listed 5–50 mm thicknesses, with plain, composite or aluminum-faced options and adhesive or non-adhesive configurations.
View High Density Rubber Foam Board
Colored Rubber Foam Board
Available in designated grey, creamy-white, green, blue, yellow, orange and black configurations, with plain self-adhesive or grid-aluminum-faced options.
View Colored Rubber Foam Board
Self Adhesive Rubber Foam Board
Rubber foam board and sheet with self-adhesive configurations for flat or shaped surfaces. Thickness, surface finish and color depend on the selected option.
View Self Adhesive Rubber Foam Board
Foil Faced Rubber Foam Board
Closed-cell rubber foam board with square or grid aluminum facing and self-adhesive backing, in listed 5–50 mm thicknesses.
View Foil Faced Rubber Foam Board
Slit Rubber Foam Pipe
Flexible elastomeric foam insulation supplied as a preformed slit sleeve. Inner diameter and insulation thickness are matched to the actual pipe size.
View Slit Rubber Foam Pipe
High Density Rubber Foam Pipe
Higher-density preformed sleeves with listed 10–110 mm inner diameters and 15–50 mm insulation thicknesses for water, solar, PPR and air-conditioning piping.
View High Density Rubber Foam Pipe
Foil Faced Rubber Foam Pipe
Aluminum-foil-faced rubber foam pipe insulation in listed sleeve diameters and 15–50 mm insulation thicknesses for water and related piping.
View Foil Faced Rubber Foam Pipe
PPR Pipe Insulation Sleeve
B1-designated preformed sleeves for PPR water pipes, with listed 6–32 mm inner diameters, 8 or 15 mm insulation thickness, and red or blue configurations.
View PPR Pipe Insulation Sleeve
Solar Water Pipe Insulation Sleeve
Preformed rubber foam sleeves for solar hot-water and related water pipes, with listed 10–110 mm inner diameters and 15–50 mm insulation thicknesses.
View Solar Water Pipe Insulation Sleeve
AC Copper Pipe Insulation Sleeve
B1-designated preformed sleeves for air-conditioning copper pipes, with listed 6–32 mm inner diameters, 8 or 15 mm insulation thickness, and red or blue options.
View AC Copper Pipe Insulation Sleeve
Water Pipe Freeze Protection Insulation
Preformed water-pipe insulation sleeves for freeze-protection applications, with listed 6–110 mm inner diameters and 8–50 mm insulation thicknesses.
View Water Pipe Freeze Protection InsulationHVAC, Refrigeration & Cold-Service Applications
HVAC & Refrigeration Systems
Elastomeric insulation is used on HVAC and refrigeration ducts, equipment and pipework where thermal and moisture control are required together. Board and sheet formats suit larger or non-cylindrical surfaces; preformed sleeves fit compatible pipework.
Cold-Service Piping & Condensation Control
On chilled-water and other cold-service lines, rubber insulation helps limit heat gain and moisture ingress where operating surfaces are colder than the surrounding air. Selection depends on pipe outside diameter, insulation thickness, operating temperature and ambient humidity. The insulation must remain continuous through seams, fittings and penetrations; product selection alone does not determine condensation performance.
Elastomeric Insulation Specifications & Supply
For an insulation inquiry, start with the relevant board, sheet or pipe product. Specify the required construction and quantities using the appropriate details below rather than treating all formats as one universal specification.
Board & Sheet Specifications
Board and sheet orders identify thickness, length and width, density, surface construction and quantity. Depending on the selected series, rubber insulation can be supplied plain, self-adhesive or foil-faced, with colors available on designated products. The backing or facing should be confirmed as part of the ordered construction.
Pipe Specifications
Pipe orders identify the actual pipe outside diameter, matching sleeve size, insulation thickness, density or product series, surface configuration and quantity. Where a project uses several pipe sizes, list each diameter and thickness combination separately against the piping schedule.
Material Data, Configuration & Packing
The current range includes closed-cell NBR/PVC rubber insulation foam products. Thermal, fire and service-condition data must correspond to the specific board, sheet or pipe construction supplied, rather than a single value being assumed for every elastomeric insulation product. For material background, refer to the NBR foam and closed-cell guidance pages.
Packing and shipment requirements depend on product form, dimensions, order quantity, transport method and destination. The final order specification should also identify any required technical or compliance documentation.
Request an Elastomeric Insulation Quote
For project or bulk supply, share the required product or application, dimensions, thickness, facing, quantity and delivery destination. Insulvora can review the relevant options and prepare a quotation based on the requested configuration.
