Slit Rubber Foam Pipe

Insulvora manufactures slit rubber foam pipe from closed-cell NBR/PVC elastomeric foam. The preformed tube has a longitudinal opening so it can be fitted from the side of a round pipe. The series is used for water, hot-water, solar-water, PPR and air-conditioning pipework, with available thicknesses and inner diameters suited to individual pipe sizes and multi-size purchasing schedules.

15–50 mm Available insulation thickness
≤0.034 W/m·K Thermal conductivity at 0°C
-40 to +105°C Service temperature range

Slit Rubber Foam Pipe Structure & Specifications

The slit rubber foam pipe is supplied in a preformed circular profile rather than as flat rubber foam sheet. Its lengthwise opening permits side fitting while the tube retains its pipe-shaped form. Select the insulation thickness and inner diameter together: each thickness is offered in a defined set of sizes, and the tube inner diameter must correspond to the outside diameter of the pipe being insulated.

Basic Product Data NBR/PVC Slit Tube
Material Closed-cell elastomeric NBR/PVC rubber foam
Density 65–85 kg/m³
Thermal Conductivity ≤0.034 W/m·K at 0°C
Service Temperature -40 to +105°C
Fire Performance B1
Product Form Preformed slit tube
Thickness & Available Inner Diameters Pipe Size Range
15 mm Thickness 10 / 20 / 25 / 32 / 43 / 48 mm inner diameter
20 mm Thickness 16 / 22 / 25 / 27 / 32 / 34 / 43 / 48 / 76 / 89 / 108 mm inner diameter
25 mm Thickness 20 / 25 / 32 / 43 / 48 / 60 mm inner diameter
30 mm Thickness 20 / 25 mm inner diameter
40 mm Thickness 26 / 34 / 44 / 49 / 60 / 77 / 90 / 110 mm inner diameter
50 mm Thickness 26 / 34 / 44 / 49 / 60 / 77 / 90 / 110 mm inner diameter

The available inner-diameter range differs by thickness. A diameter listed for one thickness should not be assumed available at every other thickness; use the combination shown above when preparing a pipe-size schedule.

Typical Applications

Preformed slit tubes are used on straight runs of water pipes, hot-water lines, solar water pipes, PPR piping and air-conditioning pipework. They can be fitted to newly installed pipework or to existing straight sections where the insulation must be placed around the pipe from the side.

Thermal Performance & Product Data

Closed-cell NBR/PVC foam reduces heat transfer through the pipe wall and helps limit water-vapor ingress. For chilled-water and air-conditioning lines, condensation control requires an appropriate insulation thickness and continuous sealing at the longitudinal slit, butt joints and fittings.

Even where the foam itself has low vapor permeability, an unsealed slit can become a direct moisture-entry path. The thermal conductivity of ≤0.034 W/m·K at 0°C and the service temperature range of -40 to +105°C refer to the stated foam substrate; they do not replace evaluation of the completed insulation construction.

Fire classification, adhesives, facings and outdoor protection should be checked for the actual installation. The longitudinal slit should be positioned away from standing water, abrasion, service-access areas and locations subject to frequent contact.

Request a Slit Rubber Foam Pipe Quote

For a slit rubber foam pipe quotation, provide the outside diameter of each pipe, the required insulation thickness and the purchase quantity for each size. Projects with multiple pipe diameters can be arranged into one size-by-size supply schedule, with each item matched to the available tube inner diameter. Include any defined service-temperature requirements and other relevant project conditions in the enquiry so the requested combination can be reviewed for quotation.