Elastomeric Rubber Foam · Board Format

High Density Rubber Foam Board

Insulvora supplies high density rubber foam board made from closed-cell NBR/PVC elastomeric foam for roof, sun-room, HVAC equipment and duct insulation. The range includes different thicknesses, colors, surface constructions and backing options for project-specific board configurations.

80–110 kg/m³Available density range
5–50 mmAvailable thickness range
-40°C to +105°CService temperature range

High Density Rubber Foam Board Specifications

Available Specification Range Rubber Foam Board
MaterialClosed-cell NBR/PVC rubber foam
Density80–110 kg/m³
Thickness5 / 7 / 7.5 / 10 / 15 / 20 / 25 / 30 / 50 mm
Thermal Conductivity≤0.034 W/m·K at 0°C
Service Temperature-40°C to +105°C
Fire PerformanceB1 · Oxygen Index ≥32
ColorsBlack / Gray / Creamy White / Blue / Green / Yellow / Orange
Surface OptionsPlain / Composite / Throwing-Plate / Grid-Aluminum Faced
BackingSelf-Adhesive / Non-Adhesive

A 50 mm thickness is available in composite or double-layer composite construction. Board length and width depend on the selected product configuration.

Typical Applications

High Density Rubber Foam Board is supplied mainly for roof and sun-room insulation, including larger or continuous areas suited to sheet-form elastomeric insulation. It is also used for HVAC equipment and duct insulation where board-form material is appropriate.

For equipment and duct applications, the supplied construction should be selected according to the actual insulation area and operating environment. Requirements involving exposed surfaces or specific appearance can also affect the choice of facing and color, subject to available configurations.

Thermal Performance & Product Data

Closed-cell rubber foam reduces heat transfer and limits water-vapor ingress. Effective condensation control still requires sufficient insulation thickness and complete sealing of joints, edges and penetrations. The thermal conductivity measured at 0°C is a reference value; design calculations should use data appropriate to the expected operating temperature. Higher density primarily affects stiffness and handling and does not necessarily provide higher thermal resistance.

The -40°C to +105°C service-temperature range applies to the foam substrate. Weather resistance, UV resistance, facing performance and adhesive performance must be confirmed separately for rooftop, outdoor or otherwise exposed installations.

B1 documentation should correspond to the construction actually supplied. For multilayer installations, avoid continuous interlayer voids, misaligned layers and lifted edges.

Request a High Density Rubber Foam Board Quote

For project and bulk orders, provide the required thickness, board dimensions or coverage quantity, surface construction, backing preference and color requirements. Finished dimensions and available surface–color combinations depend on the selected configuration.

If your project specifies fire, mechanical or condensation-control criteria, include those values along with the application and operating conditions. For rooftop or otherwise exposed installations, identify any weather, UV, facing or adhesive-performance requirements that need confirmation. Insulvora can then review the requested construction and confirm the available options for quotation.