Rock Wool · High Density Board

High Density Mineral Wool Insulation: Rock Wool Board

Insulvora manufactures high density rock wool board for building and project insulation, including supply to contractors and distributors. This high density mineral wool insulation is supplied in a standard 1.2 × 0.6 m board format, with grades selected by the required density, thickness and project performance criteria.

120–200 kg/m³ Available density range
30–150 mm Available thickness range
70–150 kPa Compressive strength

High Density Mineral Wool Insulation Specifications

The available board range and reported performance values are shown below. Specify the required grade and dimensions together with any mandatory project performance requirements.

Available Specification Range High Density Rock Wool Board
Material Rock Wool / Mineral Wool
Density 120–200 kg/m³
Thickness 30–150 mm
Standard Dimensions 1.2 × 0.6 m
Thermal Conductivity 0.038–0.045 W/m·K
Maximum Operating Temperature 600°C
Compressive Strength 70–150 kPa
Combustion Performance Class A1 (GB 8624)
Melting Point >1000°C

Typical Applications

High-density rock wool board is used in roof decks, floors, sandwich-panel cores and partitions where greater stiffness or defined mechanical performance is required alongside thermal insulation and sound absorption. The suitable grade depends on the assembly, fixing method, support conditions and expected loads.

High density alone does not establish suitability beneath waterproofing membranes, screeds or trafficked surfaces. For these installations, the board's compressive strength and point-load performance must meet the selected system's requirements. Different load zones may need different grades or installation methods.

Performance & Product Data

For high density mineral wool insulation, density should not be used as a substitute for thermal or mechanical performance data. Thermal resistance depends on thermal conductivity and installed thickness; compressive strength must be assessed separately where boards are exposed to loads.

The maximum operating temperature of 600°C applies to the rock wool material. Facings, binders and adjacent components may impose a lower limit on the finished system. Class A1 (GB 8624) describes the tested board's reaction-to-fire classification, not the fire-resistance rating of an entire assembly.

When comparing board grades, use consistent thickness, loading direction and test conditions. Match thermal, mechanical, fire and acoustic requirements to the project design rather than selecting on density alone.

Container Loading Reference

Estimated board area per container for 1200 × 600 mm boards.

Thickness20GP40GP40HQ
30 mm868 m²1,763 m²2,000 m²
50 mm521 m²1,058 m²1,200 m²
60 mm434 m²882 m²1,000 m²
80 mm326 m²661 m²750 m²
100 mm261 m²529 m²600 m²
120 mm217 m²441 m²500 m²
150 mm174 m²353 m²400 m²

For preliminary freight planning only. Figures assume 60 m³ of board volume per 40HQ; 20GP and 40GP estimates are scaled by container volume. Actual loading depends on packing, pallets, stacking and permitted payload. The final loading plan is confirmed with the quotation.

Request a High Density Mineral Wool Insulation Quote

For a project or distribution quotation, send the target density, board thickness, required dimensions, quantity and intended application. Include any mandatory thermal, mechanical, fire or acoustic requirements, along with specified test standards or target values.

Insulvora can use these details to confirm the requested board configuration for quotation and production preparation within the available specification range.