Glass Wool · Board Format · Class A Fire Performance

Fire Resistant Glass Wool Board

Insulvora manufactures fire resistant glass wool board for building projects requiring thermal and acoustic insulation in board form. Available in a range of densities, thicknesses and panel dimensions, the product serves building-envelope and partition applications. Class A fire performance to GB 8624 is part of the listed product specification; suitability should be checked against the relevant product data and complete assembly requirements.

48–100 kg/m³Available density range
20–100 mmAvailable thickness range
Class A · GB 8624Fire performance

Fire Resistant Glass Wool Board Specifications

Boards are available within the specification ranges below. Density, thickness and panel dimensions define the requested product configuration. Insulvora supplies boards for project procurement, distribution and bulk purchasing, with dimensions and quantity determined for each order.

Available Specification Range Glass Wool Board
Density48–100 kg/m³
Thickness20–100 mm
Length600–2400 mm
Width600–1200 mm
Thermal Conductivity0.038–0.045 W/m·K
Maximum Working Temperature450°C
Fire PerformanceClass A (GB 8624)
ColorYellow
PackingPVC inner bag + outer woven bag

Typical Applications

The board is used for insulation in exterior walls, partitions, curtain walls and roofs where the construction calls for a documented reaction-to-fire classification. Panels can be cut to the designed dimensions and secured in framed cavities or enclosed systems, providing thermal insulation and sound absorption.

Installation must follow the applicable system details. For construction with a tested fire-resistance period, linings, framing, joints, penetrations and fixings must match the tested assembly. Any site substitution must remain within the tested construction and approved detailing.

Thermal & Fire Performance

GB 8624 Class A describes the reaction-to-fire classification of the tested product construction. It does not establish the fire-resistance duration of a complete wall or roof. When a project specifies such a duration, separate test evidence for the entire assembly is required.

The thermal resistance of the board depends on its thermal conductivity and installed thickness. The listed maximum working temperature of 450°C applies to the glass wool material under specified conditions and must not be treated as a system fire rating.

Fire-performance reports should correspond to the density, thickness, facing and product construction actually supplied, and identify the scope, test standard and revision status. Product technical data and fire-performance test information can be supplied for the corresponding fire resistant glass wool board specification.

Request a Fire Resistant Glass Wool Board Quote

Send the required density, thickness, board dimensions and quantity for quotation. Include any specified fire-performance or technical-document requirements for the project.