Pipe System Products

Pipe Insulation for HVAC, Refrigeration and Mechanical Systems

Insulvora manufactures flexible elastomeric tubes and application-specific sleeves for HVAC, refrigeration, chilled-water, plumbing and compatible industrial services. The available range includes standard, high-density and foil-faced configurations, along with sleeves for defined piping applications.

Select the product by actual pipe outside diameter, insulation thickness, service temperature and installation exposure. Available sizes, surface options and accessories depend on the confirmed series.

Pipe insulation tube in split rubber foam form
Pipe Product Range

Pipe Insulation Products for HVAC and Water Systems

Explore seven preformed tubes and sleeves, including standard, higher-density, foil-faced and application-specific rubber foam products.

01Slit rubber foam pipe insulation

Slit Rubber Foam Pipe

Density65–85 kg/m³

This flexible pipe insulation tubing has a pre-slit, closed-cell NBR/PVC construction for compatible water, hot-water, PPR and air-conditioning pipework. Match sleeve inner diameter and insulation thickness to the pipe's actual outside diameter.

View Slit Rubber Foam Pipe
02High density rubber foam pipe insulation

High Density Rubber Foam Pipe

Density80–110 kg/m³

Higher-density preformed rubber foam for water, solar hot-water, PPR and air-conditioning pipes. The documented series covers multiple sleeve inner diameters and 15–50 mm insulation thicknesses.

View High Density Rubber Foam Pipe
03Foil faced rubber foam pipe insulation

Foil Faced Rubber Foam Pipe

Density65–85 kg/m³

Preformed NBR/PVC rubber foam with an aluminum-foil surface. The documented range includes multiple sleeve diameters and 15–50 mm thicknesses for compatible water and related piping applications.

View Foil Faced Rubber Foam Pipe
04PPR pipe insulation sleeve in red and blue

PPR Pipe Insulation Sleeve

Density65–85 kg/m³

Colored preformed sleeves for PPR water pipes, including B1-designated configurations in the documented series. Select the sleeve bore to match the actual PPR pipe outside diameter. These are application-specific plumbing pipe insulation products.

View PPR Sleeve
05Solar water pipe insulation sleeve

Solar Water Pipe Insulation Sleeve

Density65–85 kg/m³

Preformed rubber foam sleeves for solar hot-water and related water-pipe applications. Documented options include multiple bore sizes, 15–50 mm insulation thicknesses and a −40 to +105°C base-material service range.

View Solar Water Sleeve
06AC copper pipe insulation sleeve

AC Copper Pipe Insulation Sleeve

Density65–85 kg/m³

Preformed sleeves for air-conditioning copper pipes, with documented small-bore, B1-designated red and blue configurations. Match the sleeve inner diameter to the copper tube's actual outside diameter.

View AC Copper Sleeve
07Water pipe freeze protection insulation sleeve

Water Pipe Freeze Protection Insulation

Density65–85 kg/m³

Preformed, closed-cell water-pipe sleeves in multiple documented bore and thickness combinations. For outdoor freeze-protection service, specify separate weather protection or heat tracing where project conditions require it.

View Freeze Protection Product
Application Requirements

Insulation Across HVAC and Mechanical Services

Refrigeration and Air-Conditioning Lines

Cold refrigerant and air-conditioning lines need thermal control and continuous insulation through straight runs, joints, fittings and penetrations. Select flexible pipe insulation material according to line temperature, ambient humidity, actual pipe size, insulation thickness, location and required surface construction.

Chilled, Cold and Hot Water Piping

Chilled-water and cold-water lines require attention to heat gain and moisture exposure at the insulated surface. Hot-water lines require heat-loss control and suitable temperature capability. Specify product form, thickness and protection for the actual service rather than using the same configuration for both hot and cold systems.

Industrial and Outdoor Pipework

Industrial and outdoor pipework may call for mineral-wool pipe sections, flexible foam or another compatible construction, depending on operating temperature, pipe geometry and environmental exposure. These applications are not limited to the elastomeric sleeves listed above. Specify facing, jacketing or cladding when weather or mechanical protection is part of the project scope.

Order Definition

Pipe Size, Thickness, Documentation and Supply

For each line item, identify the selected series, pipe outside diameter, sleeve bore, insulation wall thickness and quantity. The following checks establish technical suitability and the information needed for supply.

Dimensions and Thermal Requirements

Select insulation thickness using operating temperature, ambient temperature and humidity, available installation space and the project's thermal target. Any R-value or engineering calculation must refer to the material data, stated conditions and calculation method used for the project.

Surface, Joints and Environmental Exposure

Record whether the chosen product is plain, faced or otherwise protected. Where included in the supply scope, coordinate joint closure, vapor-control continuity, fittings, valves, supports and penetrations with compatible tapes, finishes or external protection.

Factory Review, Packing and RFQ

For quotation and production planning, Insulvora confirms the agreed product series, dimensions, labeling, packing and required technical or compliance documents. Include the application, destination country or port, and any approved sample or special packaging requirements in the RFQ.

Request a Mechanical Piping Quote

Source elastomeric tubes and sleeves for HVAC, refrigeration and compatible water piping. Contact Insulvora to discuss suitable product options and request a project or bulk-supply quotation.